Introduction
The LifePak CR-T AED Training System
provides realistic training in the use of the LifePak CR Plus defibrillator
without the actual charge and discharge of electrical energy.

Product
Overview and Description
The LifePak CR-T AED Training System is realistic, versatile, dynamic, easy
to use, and developed by trainers for trainers.
The CR-T mimics the appearance
of the CR Plus and simulates actual operations of the CR Plus. The CR-T
follows the simple 1, 2, 3-step operation of the CR Plus and guides users
through simulated analysis, energy delivery and prompted CPR intervals.
All of its functions are programmable to simulate the full range of scenarios
possible during "real life" use of the LifePak CR Plus defibrillator.
The CR-T enables you
to run preconfigured training scenarios and to create dynamic custom scenarios
of your own. Using a wireless remote control, you can interrupt preconfigured
routines to simulate events such as patient motion or electrode disconnection.
The CR-T is a cost-effective training solution. It is powered by four
standard D-cell batteries. The electrodes are affordable and reusable,
and mimic the rapid access QUIK-PAK pacing/defibrillation ECG electrodes
unique to the LifePak CR Plus defibrillator.
The CR-T provides realistic
and versatile training for all skill levels. It is designed to meet the
needs of all trainers, for teaching both first time lay users and refreshing
experienced emergency responders.

Features
and Benefits
 |
Dynamic and versatile
training tool |
 |
Simulates the LifePak
CR Plus AED in appearance and operation |
 |
Low operating cost |
 |
Incorporates scenarios
from the American Heart Association's HeartSaver AED course and the
American Red Cross CPR/AED courses |
 |
Same intuitive and
simple 1-2-3-step operation as the LifePak CR Plus AED |
 |
A wireless remote
control enables flexible, dynamic custom training scenarios |

Frequently
Asked Questions
| Q: |
Can
you buy replacement disposables for the CR Plus Trainer? |
| A: |
Yes. Here are common
replacement items:
Replacement Training Electrodes /adult 54-071
Replacement Training Electrodes /child 54-056
Replacement Cable assemble for child training electrodes 54-057
|
| Q: |
How
do I set my trainer to "automatic" mode? |
| A: |
Setup:
General Operating Settings
The procedure for changing the general operating settings (Start
Prompt, Pulse Prompts, Monitoring and Automatic/Semiautomatic Model)
is the same for each. Table 9 identifies each general operating
setting, indicates the LED bar that corresponds to the setting,
and describes the options available.
Table 9 General Operating
Setting Options
| Operating
Setting |
Bar
Number
|
Options |
| Automatic/Semiautomatic
Model |
1
|
Green
= Semiautomatic:
Red = Automatic |
| Start
Prompt |
2
|
Green
= Voice ON:
Red = Voice OFF |
| Pulse
Prompts |
3
|
Red
= CHECK FOR PULSE
Yellow = CHECK FOR SIGNS OF CIRCULATION
Green = CHECK FOR BREATHING |
| Monitoring |
4
|
Green
= ON:
Red = OFF
|
To change the general
operating settings:
| 1. |
Press the
GREEN SELECT button. |
| 2. |
Press the
VOLUME button (OPT.L) |
| 3. |
Press the
RIGHT4ARROW button to
advance the desired operating setting (LED bar number). |
| 4. |
Press the
UP5ARROW button to select
the desired option (LED bar color). |
| 5. |
Repeat steps
3 and 4 until you have changed all of the desired operating
settings. |
| 6. |
After making
your changes, press the GREEN SELECT button to save the selections.
The signal sensor flashes, indicating the selections have been
saved. The Trainer enters simulated OFF status. |
Figure 11 shows the
LED displaying the following option settings:
 |
Bar 1, Automatic/Semiautomatic
Model: Semiautomatic (green) |
 |
Bar 2, Start
Prompt: Voice ON (green) |
 |
Bar 3, Pulse
Prompt: CHECK FOR BREATHING (green) |
 |
Bar 4, Monitoring:
OFF (red) |

Figure 11 General
Operating Setting Options
|

Technical
Specifications
General
Device designed for low impact, low stress environments. For use in temperature
controlled areas protected from precipitation. Capable of withstanding heavy
usage and prolonged periods of operation.
Physical Characteristics:
Height: 10.7 cm (4.2 in)
Width: 20.3 cm (8.0 in)
Depth: 24.1 cm (9.5 in), excluding handle
Weight: 2.1 kg (4.6 lb), with batteries
Batteries: 6 volts/4
cells, range 3.4- 6.5 Vdc. Four nonchargeable D-cell alkaline batteries.
New batteries will provide not less than 100 hours of continuous operation
under normal, indoor-environment conditions.
Buttons: Master
ON/OFF, Lid Release/ON-OFF and SHOCK
Displays:
OK Indicator: Simulates an indicated OK status.
Charge-Pak Indicator: When displayed, simulates a need to replace
Charge-Pak battery charger.
Attention Indicator: When displayed, simulates at least 6 shocks
remaining or 42 minutes of operating time.
Service Indicator: Simulates that service is required.
Speaker: Volume output: High, Medium, Low
Operating Temperature: 3 to 38 degrees C (37 to 100 degrees F)
Storage Temperature: -10 to 60 degrees C (14 to 140 degrees F).
Remove batteries for storage.
Water Resistance: Spill resistant per IEC 601-1, part 44.3.
Remote Control
Transmission: Wireless infrared signal. Range: 3 meters (10 ft)
maximum. 82 in (2 meters) optional cable attachment.
Size: 4.57 cm x 3.38 cm x 1.65 cm (1.8 in x 1.3 in x .6 in)
Weight (without batteries): 32 gm (.08 lb)
Batteries: 3 volts supplied by two AAA alkaline batteries.
Buttons: 13-key membrane switch pad labeled for the following functions:
NO SHOCK, SERVICE REQUIRED, ELECTRODE PAD CONTACT, MOTION, REPLACE CHARGE-PAK,
LOW INTERNAL BATTERY, CPSS, PAUSE, VOLUME CONTROL, SETUP NAVIGATION BUTTONS.
Operating Temperature: 3 to 38 degrees C (37 to 100 degrees F)
Storage Temperature: -10 to 60 degrees C (14 to 140 degrees F).
Remove batteries for storage.
Water Resistance: Spill resistant per IEC 601-1, part 44.3.

Articles
/ Sales Brochure / Manual /
Click
here to view a sales flyer on the LIFEPAK CR PLUS Trainer.

Product
Ordering Information
| SH
Catalog # |
Product
Name |
| 54046 |
LifePak
CR PLUS Trainer |
| 54071 |
Replacement
Training Electrodes /adult
|
| 54056 |
Replacement
Training Electrodes /child |
| 54057 |
Replacement
Cable assemble for child training electrodes |
|