School Health
Login/Register My Account View Order Order Status Contact Us Catalog Request
Health Giant Health Giant Go To School Health
School Health
Online Catalog Quick Order Online Tour
Search Products  
Search Assistant
Online Specials
New and Featured Products
Asthma and Diabetes Management
Emergency Response and Safety
First Aid and Bandages
Furniture and Equipment
Health Education Resources
Hot/Cold and Hydro Therapy
Hydration and Nutrition Products
Infection and Infestation Control
Paper and Plastic Products
Rehab Equipment and Supplies
SH Pharmacy
Sports Medicine Supplies
Vision and Hearing Screening
Vital Statistics and Health Assessment
Complete Product List
Need Help? Phone: 1-800-323-1305 or Email
School Health-Product Education-Welch Allyn DuraShock Sphygmomanometer
 
Welch Allyn Spot Vital Signs

Introduction
Product Use and Procedure
Features and Benefits
FAQ's
Technical Specifications
Warranty
Customer Testimonial or Example Uses
Other Information
Product Ordering Information
Email This Page Send Us Your Feedback
Print This Page Ask Our Product Specialist


Introduction

Welch Allyn has taken the concept of vital signs diagnostics and streamlined the technology to introduce a fully automated, multi-use instrument at a practical price. The Welch Allyn Spot Vital Signs Monitor does a non-invasive blood pressure (NIBP) test using the oscillometric method; takes pulse rate and mean arterial pressure; takes oral, rectal and axillary temperatures using the Sure Temp Thermometer; and tests Pulse Oximetry, SpO2 all within approximately 30 seconds. It is lightweight with a convenient built-in handle. It is easy to learn and simple to use. The automated Spot Vital Signs Monitor gives you more time to spend on patient care.



Product Use and Procedure
Welch Allyn's Spot Vital Signs device delivers vital signs in seconds. The basic unit offers noninvasive blood pressure, pulse rate and mean arterial pressure (MAP). Spot Vital Signs additional parameters include SureTemp™ thermometry and/or Nellcor® Pulse Oximetry. An optional external printer is available for record keeping purposes. The following list shows the basic operation and readings on a SPOT unit.
On/Off Button- controls power to the device.
Print Button-
Pressing this button initiates print operation.
Mode Button-
Pressing this button down for 2 seconds turns backlight off/on. With temperature probe removed from holder, pressing this button switches thermometer from oral to auxiliary. To bring the Spot Vital Signs out of standby/sleep mode, press this button.
Next Patient/Clear Button-
Clears all data from the device. Always press clear before taking vitals on a new patient.
Blood Pressure Operation-
To take blood pressure measurement, press BP Start/Stop. Button. Press this button again if you need to stop the blood pressure measurement.
Temperature Operation-
Make sure the appropriate temperature probe is connected to the device (Blue = Oral/Axillary, Red = Rectal), remove probe from holder and apply a new probe cover, properly place probe in mouth as directed in operator manual. When done a single beep will be heard and temperature is displayed, eject probe cover and return probe to holder.
SpO2 Operation-
Apply sensor to patient and insure adequate signal from pulse signal bar graph. SpO2 measurement and pulse rate will update continuously for 10 minutes.

Error Codes
When responding to an error code, always check the patient first and then proceed to check the device.

Blood Pressure Error Codes

C02 Autozero failure: Check for air obstruction, limit patient movement.
C03 Inflation too rapid: Check for kinked hose or air obstruction.
C04 Excessive inflation time: Check for air leaks.
C05 Excessive noise: Check patient condition, cuff placement, limit patient movement.
C06 Measurement outside of device's range: Check patient condition.
E10 Cuff Overpressure: Check patient condition

Temperature Error Codes

C20 Broken/Missing Probe: Replace Probe
P Loss of tissue contact: Insure proper probe positioning.
E0.2 Ambient Temperature out of range: Adjust temperature or device location.
E0.3 Ambient Temperature out of range: Adjust temperature or device location.
C22 10-minute diagnostic limit exceeded: Check patient. Read operator manual. Be sure that this device is not being used for monitoring purposes.


SpO2 Error Codes

C6 Sp02 heart rate out of range.
E7 Internal Malfunction: Contact Customer Service.
C9 10-minute diagnostic limit exceeded: Check patient. Read operator manual. Be sure that this device is not being used for monitoring purposes.

General Error Codes

E11 Internal safety violation: Check patient, contact Customer Service.
C12 Ambient Temperature out of range: Adjust temperature or device location.
C13 Battery Failure: Use wall transformer.
E0.0-E9.9 Temperature Module Malfunction: Contact Customer Service.
E20-E50 General Internal Malfunction: Contact Customer Service.




Features and Benefits

Affordable- Hospital-quality automated vital signs at a breakthrough price.
Simple & User-Friendly- Easy and straightforward operation that insures consistent, accurate measurements.
Easy to Follow Training Video- Have your staff trained to run Spot Vital Signs Monitor in under 10 minutes!
Upgradeable- Easily upgradeable to meet your facilities changing needs.
Modular/Multiparameter- Choose the parameters to meet your facilities needs.
Flexible Mounting Options- Spot Vital Signs Monitor is available where and how you need it! Carry it, or mount it on a mobile stand, I.V. Pole mount or wall mount.
Sure Temp Technology- Accurate 4-second oral temperatures means increased efficiency.
Increases Your Staff's Speed & Efficiency- Results on NIBP, SpO2 and Temperature in 30 seconds.
Nellcor Pulse Oximetry- Accurate and durable SpO2 measurements with a wide variety of sensors.



Frequently Asked Questions
Q: I need a unit that is very portable and lightweight. How much does the complete SPOT unit weigh?
A: The unit weighs only 4 lbs and has a convenient built in handle making it very portable.

Q: How long does it take the battery to charge?
A:

In normal situations it takes about 8 hours for a full charge. If the battery is completely drained, it takes about 12 hours.

Q: How long will a fully charged battery last?
A: A fully charged battery will last approximately 150 cycles.

Q: Does the SPOT contain the new motion tolerant SpO2 technology from Nellcor?
A: SPOT units manufactured after mid-October of 2002 contain the Nellcor motion-tolerant MP506 sensor.

Q: : I do not need the Pulse Oximetry function in the SPOT unit, can it be ordered without the Pulse Ox?
A: Yes! The SPOT can be ordered in any configuration that meets your needs. Call the School Health sales department to discuss the available configurations.
Q: I want to use my SPOT unit to track results when I am taking my athletes' vital stats during physicals. Is there a printer so I can print the test results?
A: Yes. It is a wireless printer that communicates remotely with the SPOT unit. You can order this accessory from SH, catalog # 52-318.
Q: What kind of disposable probe covers do I use with the Thermometer component?
A: The SPOT uses a SureTemp thermometer disposable probe covers #21-178 or #21-177. They can be ordered from SH Corporation.
Q: How do I find out more about the SureTemp Thermometer used in the SPOT unit?
A: Visit our product education page on the SureTemp Thermometer by clicking here.




Technical Specifications
The Welch Allyn DuraShock integrated aneroid sphygmomanometer is accurate to ±3 mm Hg and conforms to applicable sections of the following standards for aneroid sphygmomanometers:

Dimensions: height: 9.70 in (24.64 cm) x length: 5.72 in (14.53 cm) x width: 4.73 in (12.01 cm)
Weight: 4.25 lbs. (1.91 kg)
Blood Pressure Accuracy: Meets or exceeds SP10-1992 AAMI standards
Cuff Pressure Range: 0-300 mmHg
Systolic Determination: Max: 250 mmHg Min: 60 mmHg
Diastolic Determination: Max: 160 mmHg Min: 30 mmHg
Pulse Rate Accuracy: SpO2 Module Heart Rate: +/- 3.0 bpm
Blood Pressure Algorithm: +/- 5.0 bpm
Pulse Rate Determination: Max: 245 bpm Min: 25 bpm
Temperature Accuracy: Meets or exceeds ASTM E112-86 standards
Pulse Oximetry Accuracy: Nellcor Puritan Bennett Pulse Oximeter Module: +/- 3% in the range of 70-100% Oxygen saturation (1 standard deviation) < 70% unspecified by the OEM
Power Requirements: North American Version: 120 VAC, 60 Hz
International Version: 230-240 VAC, 50 Hz
Internal Battery: Lead Acid, with external charger



Warranty
The Welch Allyn Spot Vital Signs instrument is backed by a full two-year warranty on all parts and labor. If warranty service is required, a loaner will be provided at no charge.



Customer Testimonial

"We love the convenience. Being able to automatically collect all the Vital Signs in a short amount of time really frees up the nurses" - Laurie McGraw, RN (Minong, WI).



Other Information
To learn more about the SPOT Vital Signs unit click here to view a slide show about the unit on Welch Allyn's website.



Product Ordering Information

SH Catalog # Product Name
53106 Welch Allyn Spot Vital Signs, NIBP/ Nellcor Pulse Oximetry/ Temperature
53112 Welch Allyn Spot Vital Signs, NIBP only (Pulse Rate and MAP)
53113 Welch Allyn Spot Vital Signs, NIBP/ Temperature
53114 Welch Allyn Spot Vital Signs, NIBP/ Nellcor Pulse Oximetry

 

 


Login/Register | My Account | View Order | Order Status | Contact Us | Catalog Request | Online Catalog
Quick Order | Online Tour | Customer Service | Education and Resources | What's New | Company Info
Search Assistant | Terms and Conditions | Privacy Policy | Site Map | Home

Site Design and Development by AccuVis