School Health-Product Education- Maico MA-39 Audiometer
 
Maico MA-39 Audiometer

Introduction
Product Overview and Description
Product Use and Procedures
Features and Benefits
Frequently Asked Questions
Technical Specifications
Articles
Other Information
Warranty
Reimbursement
Product Ordering Information
Email This Page Send Us Your Feedback
Print This Page Ask Our Product Specialist


Introduction

The MA 39 from Maico Diagnostics is part of a series of portable screening audiometers that allows you to choose which has the features that best meet your needs. The MA 39, for example, provides basic air conduction. Conduct a testing battery including pure tone screening and air threshold.




Product Overview and Description
The Model MA 39 is a precision instrument designed to permit simple, rapid and reliable hearing tests. Their application ranges from school testing programs, pre-employment examinations and monitoring audiometry for hearing conservation programs. The instrument provides all of the pure tone frequencies and full dynamic range specified by the American National Standards Institute S3.6 1996.

Features include, a full range electronic attenuator (-10 dBHL to 110 dBHL mid frequencies), with all input/output switching and routing performed electronically. Large LED* numeric displays show the selected frequency and HL intensity. Small individual LED's are used to show the selected function (See Figure 1). The model MA 39 retains the side mounted controls for frequency and HL setting as well as the dual present/interrupt buttons so familiar to Maico audiometer users. All functions, actuators/push button controls, provide a tactile feedback to the operator whenever a function is selected or operated. In addition a bright LED indicator is associated with the selected function.

Maico audiometers have been designed to meet the most rigorous of electrical safety standards and to provide years of reliable operation with a rugged durability that has become the trademark of Maico portable audiometers.



Product Use and Procedures
Set Up
Place the MA 39 on a stable counter or table. Open the side latches and fold the lid back. Fold the lid back one more time to reveal the accessories that are packaged within the rear storage compartment. If you haven't already done so, unpack and inspect the accessories.

The TDH 39 headphones are serialized and should match the serial number on the instrument. Check to see that the numbers match, as this will confirm that the headphones and MA 39 were calibrated together. The optional insert phones do not have a serial number, but if they were ordered at the same time as the MA 39 they were calibrated to that particular instrument and should not be used on another without recalibration.

Turn the MA 39 around so that you can view the rear jacks. Insert the RED (right) plug of the TDH 39 headset into the right air conduction earphone jack labeled R, under AC (Air Conduction). Insert the BLUE (left) plug into the left AC earphone jack labeled L.

The insert phones are installed in the same manner. Insert the RED (right) plug of the insert phone cord into the insert phone jack labeled R, under INS (INSert phones). The BLUE (left) plug is inserted into the jack labeled L.

Patient Response Switch - Optional - Locate the PATIENT RESPONSE jack on the rear panel and insert the plug end of the switch.

Sound Room Patch Cords - Optional - When using the MA 39 in a sound room, connect the patch cords from the sound room to the proper right and left earphone/insert phone jacks, patient response jack.

Air Conduction Testing
Air conduction testing is used to measure the patient's hearing threshold levels. The test is usually started on the ear with better hearing.

1. Turn the MA 39 on and let it warm up for 10 minutes before using. Upon power-up the initial setting will be in audiometric testing mode, right phone, 1 KHz, 30 dB intensity.
2. Seat the patient so that he/she is facing away from the instrument at a 90° angle and cannot see what the operator is doing. Give a brief description of what the patient can expect to hear. Using a consistent explanation will help provide more reliable results. Instructions may be expressed as follows: "I am going to place these headphones on your ears. You will hear a tone or beeping sound, which may be loud or soft. Whenever you hear, or think you hear one of these tones, raise your hand. Lower it when you no longer hear the tone. Listen carefully because some tones are very soft."
3. Eliminate any obstructions that could interfere with placement of the earphone cushion on the ear (i.e. hair, earring, eyeglasses, hearing aids, etc.). Adjust the headband so that the earphone cushions are centered over the ears (RED on the right ear, BLUE on the left) and the receivers line up with the ear canals. The headband should rest firmly over the center of the head and place firm pressure on both ears.
4. Choose PULSE and/or FM if you wish. Set the INTENSITY and FREQUENCY to the desired level.
5. Press STIMULUS to present the test tone. The STIM LED should light. If the patient hears the tone he/she will raise their hand or press the patient response switch, indicated by the patient response LED.

The most commonly used hearing threshold procedure is called a modified Hughson-Westlake procedure.

1. Start at 1000 Hz with a level of 0 dB and present a signal for at least 1 second. If no response, increase in 10 dB steps until the patient responds.
2. Increase another 10 dB for a confirmation and orientation. If the patient responds again, decrease the presentations in 10dB steps until the patient no longer responds.
3. Increase in 5 dB steps until the patient responds. Once the patient responds, descend 10 dB until there is no response. Increase again in 5 dB steps.
4. Repeat until you have 2 out of 3 ascending responses at the same level. Change the frequency and repeat above procedure until you have thresholds for the number of frequencies that you wish to test.

The hearing threshold is defined as the lowest hearing level at which the patient responds to two out of three ascending stimuli at the same level.




Features and Benefits
The MA 39 comes standard with a built-in RS232 interface for PC and NOAH compatibility. For portability, the MA 39 comes standard in a soft case which makes the total weight only 9.9 pounds including accessories. Other features include:
quiet, reliable electronic switches
insert phones capability
bright, easy to read display screen
side control dials are ergonomic for maximum comfort
hard carrying case available
one year limited warranty



Frequently Asked Questions
Q: What is the frequency accuracy of the MA-39?
A: The frequency accuracy is ±1% maximum of indicated frequency.

Q: How much does the unit weigh?
A: There are 2 cases, in the soft case the unit is only 9.9lbs. The weight in the hard sided carrying case is 16.5 lb/7.5 kg.

Q: Can the unit be used in a standard electrical outlet?
A: This Maico instrument has been designed to meet the most exacting electrical safety requirements for patient care equipment. The hospital grade, 117 volt alternating current, three-prong plug (or the appropriate plug for your country) should be inserted into a mating three-prong hospital grade receptacle that is properly grounded. This will ensure reliable and safe operation of this precision instrument. Injury to personnel or damage to equipment can result when a three-prong to two-prong adapter is connected between the power plug and an AC outlet or extension cord.

Q: How do I use the Pulse or FM tone function on my MA-39?
A: PULSE/FM. Enables PULSE and/or FM stimulus.
PULSE LED on Pure tone stimulus will be pulsed.
FM LED on Pure tone stimulus will warble.
Both PULSE and
FM LEDs on
Pure tone will pulse and warble.
Both LEDs off Pure tone stimulus only.

Q: How do I prepare a person for a screening?
A: The operator should place the person to be tested at ease concerning the test. The operator should explain the purpose of the test and what kind of sound or sounds will be heard. An unvarying and uniform explanation to the person being tested will provide test results that are consistently high in reliability. An explanation for pure tone or baseline audiometry might be expressed as follows: "I am going to place these headphones on your ears. You will hear a whistle or beeping sound that may be loud or soft. Whenever you hear or think you hear one of these sounds, raise your hand (or press the response switch button) and lower your hand (or release the button) when you do not."

Q: We test in the gymnasium and it is often noisy. Will this affect our screening results?
A: Excessive sounds or noise in the chosen test environment can produce a masking effect and therefore affect the test results. The selected site should be away from conversations, noisy business equipment, hallway traffic and other noise producing environments. The lower test frequencies are most affected by these types of noises.

In some instances it may be necessary to acoustically treat the test site in order to achieve the necessary quietness for testing purposes. Commercially available "sound rooms", which are designed to provide an acoustically treated testing environment, are recommended where baseline or threshold audiometry is required. These rooms are available in a variety of sizes and isolation capabilities.

Q: When do I know I have reached the child's threshold?
A: You can check the specific requirements and state guidelines with your state health departments. Often states have different screening and threshold requirements. As a standard, the hearing threshold is defined as the lowest hearing level at which the patient responds to two out of three ascending stimuli at the same level.

Q: What maintenance is recommended with this unit?
A: To maximize the service life of your audiometer and accessory equipment, we suggest the following:
1. Turn off the instrument overnight.
2. Wipe the headset cords, ear cushions and casing occasionally with a cloth dampened (not dripping wet) with warm water. Dry with a soft cloth.
3. Leave the accessories such as the headset, permanently connected to the audiometer to minimize strain on the connections. It is not necessary to disconnect accessories not in use while performing other tests. Should it be necessary to disconnect cords, always grasp the barrel of the plug - never pull the cords. Never drop or snap the headphones together. Mechanical shock may change the earphone's electrical and operational characteristics and require calibration of the MA 39.
4. Close the audiometer cover at the end of each day to minimize dust collection.
5. Avoid sharply bending or twisting any of the cords. Although they are designed to be highly flexible, rough treatment may cause damage. Broken or defective cords can cause crackling noise and intermittent or weak operation in the headset. Headset cords may be replaced without re-calibrating the audiometer
6. This Maico audiometer has been designed to meet the most exacting electrical safety requirements for patient care equipment. The hospital grade 117 volt AC three prong plug should be inserted into a mating three prong hospital grade receptacle that is properly grounded. This will ensure reliable and safe operation of this instrument.
The use of a three prong to two prong adapter should be avoided, and is not recommended.
7. Also a yearly calibration is recommended. See information under the heading "other information".


Q: How do I clean my MA-39?
A: First, disconnect the power cord before cleaning. Clean the instrument, headphones, and other accessories with a soft cloth dampened with a little warm, soapy water. Do not use alcohol to clean.

The ear cushions of the headphones can be detached for cleaning. To remove, gently pull the cushion away from the headphone. To re-assemble, press it back onto the headphone. Make sure that the sound outlet hole sits exactly in the middle of the earphone.




Technical Specifications
Frequency accuracy ±1% maximum
Attenuator linearity ±0.5 dB per 5 dB step
Distortion 0.5% typical, 2% maximum
Rise/fall time 35 msec. typical
Frequency modulation ±5% triangle wave modulation at 5Hz
Voltage requirements 117/234 volts AC, switchable
Frequency range 125Hz to 8kHz
Hearing level range:
Air conduction -10 to 110 dB HL
Bone conduction -10 to 70 dB HL
Narrow band noise -10 to 100 dB HL



Articles
Click HERE to view the sales flyer on the MA-39.

Click HERE to review the MA-39 operation manual.



Other Information
Calibration
The optimum length of time between calibrations for audiometers varies, depending upon the treatment given the instrument and the headphones. It is recommended that the instrument have a laboratory calibration at least once every year. Since rough handling, such as dropping the headphones, can easily cause calibration errors it is advisable to establish a biological calibration check as soon as you receive the instrument. Should you feel at a later date that the audiometer's calibration might be in error, perform a biological check on a known ear. If all re-tests show major changes, calibration is probably in error. All repair and calibration should be done at an authorized Maico Special Instruments Distributor service center, such as School Health Corporation. This assures the use of quality materials by trained and experienced technicians using the proper, accurate equipment.

Additional information can be seen on the Maico website at www.maico-diagnostics.com.



Warranty
One year limited warranty extended to the original purchaser on the instrument, by Maico, through the distributor from whom it was purchased. The warranty covers defects in material and workmanship for a period of one year from the date of delivery of the instrument to the original purchaser. Accessories which are purchased from Maico at the same time as the instrument are warranted for one year from the date of purchase.




Reimbursement
The MA 39 is CPT code reimbursable for the following codes:
92551 - Screening, pure tone
92552 - Threshold, air



Product Ordering Information
SH Catalog # Product Name
51082 Maico MA 39 with soft case
51000 Maico MA 39 with hard case

 

 


Login/Register | My Account | View Order | Order Status | Contact Us | Catalog Request | Online Catalog
Quick Order | Online Tour | Customer Service | Education and Resources | What's New | Company Info
Search Assistant | Terms and Conditions | Privacy Policy | Site Map | Home

Site Design and Development by AccuVis