School Health-Product Education-MA-25 Maico Audiometer
 
MA-25 Maico Audiometer

Introduction
Product Overview and Description
Product Use and Procedure
Features and Benefits
FAQs
Technical Specifications
Warranty
Reimbursement

Product Ordering Information
Email This Page Send Us Your Feedback
Print This Page Ask Our Product Specialist


Introduction

The MA25 from Maico is School Health's smallest, most lightweight pure tone audiometer. This ultra-portable pure tone screener is ideal for the professional on the go, or school nurses that must screen at multiple locations.




Product Overview and Description
The MA 25 Audiometer is an electrical audiometer that measures the threshold of hearing for pure tone frequencies and loudness. It is an air conduction audiometer where the sounds are transmitted through earphones.

Ready to travel in its own leather-look case, the MA25 weighs in at only 3.6 lb. Although small, the MA25 is engineered to be tough and reliable. Enhancing its portability, the MA25 can be powered by either a 9V battery, or the optional AC adapter. User-friendly over-size knobs make adjusting frequency and hearing levels simple. Easy push buttons allow the user to switch between right/left, pulse tone and warble.

Although small and portable, the MA25 offers a full range of testing opportunities. Frequency levels range from 250 Hz to 8000 Hz, and signal intensities run from 10dB HL to 90dB HL.




Product Use and Procedure
Screening instrument for use in identification audiometry programs.
Used for early identification of hearing impairment.

Routine Uses:
Air Conduction Screening Testing
Screening tests are used to quickly identify those who may have a hearing problem. For this purpose the hearing level control is set to a fairly low setting but a level that most people can hear. If the patient hears the test frequencies presented in each ear, his/her hearing can be considered normal or nearly normal. If the patient does not hear the frequencies, he/she should be given a more thorough test. Remember, at this point you are merely screening the hearing, not trying to determine the lowest possible sound level they can hear. The idea is just to determine if the basic test frequencies at a fixed presentation level can be heard.

Procedure
Screening testing is typically done at four testing frequencies in each ear. The usual frequencies tested are 500, 1000, 2000 and 4000 Hz. The fixed presentation level is usually in the range of 20 to 30 dB HL, depending upon the test environment and the purpose of the screening test.

Determining what constitutes failure of a screening test is a matter of professional judgment and should be decided upon before the screening program begins. A common rule to follow is that the screening test was failed if two or more frequencies in both ears are not heard. Those not passing the screening test may or may not have a significant hearing loss, but they should be referred to have a more comprehensive audiometric test.

Air Conduction Threshold Testing
A threshold test determines the softest sound a person can hear at the test frequencies presented. Because the sound is at the level where the person can barely hear it, the threshold is usually defined as the lowest level at which the presence of the tone can be correctly recognized during half of the presentations at a specific level.

Procedure
Set the frequency selector switch to 1000Hz and the output selector switch to the ear being tested first. Set the hearing level control above the presumed threshold (such as 40 dB) then present the tone. Decrease the level by 10 dB and present the tone. If there is no response, raise the level by 10 dB, and ascend in 5 dB steps. After two or three series at the same test frequency, you should get a consistent level at which the patient first responds during the ascending presentations, and that is the threshold for that frequency.

Audiogram Form
An audiogram is used to record the thresholds determined. Each threshold measurement is marked on the audiogram before making the next threshold determination.



Features and Benefits
Pulse tone, warble operation.
Fingertip operation of Frequency and HL control.
Push button selector switches.
Front controls are easy to understand and simple to use.
Exceptionally lightweight, only 3.6 lbs.
Battery operated, optional AC adapter.
Carrying case included.



Frequently Asked Questions
Q: Sometimes I have to leave the testing area for a sick child and when I come back the unit does not work. Why does this happen?
A: An automatic power shut off occurs after 5 minutes of inactivity with the audiometer to conserve battery life. To turn the audiometer back on, the Power/Intensity switch must be turned to the OFF position and then back to any desired intensity level.

Q: How often should the unit be calibrated?
A: An electronic calibration check is recommended yearly to determine if a deviation from the standard exists. The length of time that an audiometer should be operated before recalibration varies depending on the treatment given to the unit. School Health has an authorized service center for repairs and calibrations. Click here to view information.

Q: The earphones do not seem to be working but I have a set from another audiometer, can I use those?
A: The earphones are an important and integral part of each audiometer. Earphones cannot be exchanged between audiometers.

Q: Sometimes, especially when I test in a busy school, I do not get desired results. How can I prevent this from occurring?
A: Excessive sounds or noises in the chosen test site can produce a masking effect and therefore affect test results. The selected site should be away from conversations, hallway traffic and other noise producing environments. The lower test frequencies are most affected by these types of noise.



Technical Specifications
Frequency Accuracy: +/- 2% maximum
Rise / Fall time: 35 msec typical
Distortion: .5% typical, .3% minimum
Crosstalk: - 100 dB minimum
On / Off Ratio: 90 dB minimum
Frequency Modulation: +/- 5% frequency modulating rate at 5 Hz
Voltage Requirements: 9 V alkaline battery (100 hours typical), optional AC
Dimensions: 9.5" W X 3.7" H X 6.75" D
24cm W X 9cm H X 17cm D
Weight: 3.6 lb / 1.6 kg
Frequency Range: 250 Hz to 8000 Hz
Hearing Level Range: -10 dB HL to 90 dB HL



Warranty
ONE YEAR LIMITED WARRANTY: This warranty is extended to the original purchaser of the instrument, by Maico, through the Authorized Distributor from whom it was purchased. The warranty covers defects in material and workmanship for a period of one year from date of delivery of the instrument to the original purchaser. Accessories, which are purchased from Maico at the same time as the instrument, are warranted for one year from the date of purchase. For additional information contact your authorized Maico Distributor.



Reimbursement
The reimbursement code used with the MA-25 is #92551, Screening Audiometry.




Product Ordering Information
SH Catalog # Product Name
51024 Maico (MA-25) Pure Tone Screener

 

 


Login/Register | My Account | View Order | Order Status | Contact Us | Catalog Request | Online Catalog
Quick Order | Online Tour | Customer Service | Education and Resources | What's New | Company Info
Search Assistant | Terms and Conditions | Privacy Policy | Site Map | Home

Site Design and Development by AccuVis